Automatic Power Factor Controllers (APFC)

A key component for accurate and efficient control and monitoring of capacitor banks

The automatic power factor controller (APFC) is one of the most vital components of the power factor correction equipment. As such, it plays a key role in the controlling and monitoring of the “Cos φ” (power factor) and the system power quality.

We offer the most powerful & complete and user-friendly range of APFC controllers. Thanks to the user interface upgrade with graphical icons, it is possible to commission the APFC controller without a manual. A slimmer casing requires less space in the capacitor bank panel. The APFC retains all its widely accepted functionalities and continues to deliver an easy-to-install, easy-to-use and smarter power factor controller to the market.

Applications

The APFC standard range of controllers can be used to control the phase angle (cos φ) in industrial and commercial networks. Application examples include power factor control in buildings, the mining, steel, chemical, pulp and paper, cement, plastics, printing, and food industries.

Why APFC?

The power factor controller APFC comes with the following:-

  • Direct connection for all network voltages from 100V to 440V. Connection to higher network voltages possible through voltage transformer.
  • Measurement and display of key parameters (voltage, current, power factor, THDV and THDI)
  • Fully programmable switching sequence
  • Easy commissioning
  • Complete auto set-up
  • Easy to use thanks to user-friendly interface
  • Highly efficient switching strategy combining integral, direct, linear and circular switching
  • Suitable for hot environments
  • Not affected by harmonics
  • Alarm contact

 

Specification Data:-

PARAMETERS

VALUE

Measuring system

Micro-processor system for balanced three-phase networks or single-phase networks

Operating voltage

100V to 440V

Frequency range

50 or 60 Hz

Current input

1A or 5A (RMS)

Current input impedance

<0.1 Ohm (recommended CT class 1.0, 10 VA min)

Consumption

8 VA max

Output contact rating

Max. continuous current: 1.5A
Max. peak current: 5A
Max. voltage: 440 Vac
Terminal A is rated for a continuous current of 16A

Alarm contact

Normally open contact
Max. continuous current: 5A
Rated/max. breaking voltage: 250Vac/440Vac

Starting current setting (C/k)

0.01 to 3A
Automatic measurement of C/k

Number of outputs

From 3 to 12 outputs

Power Factor setting

From 0.7 inductive to 0.7 capacitive

Switching sequences

User defined

Power outage release

Quick automatic disconnection in less than 20ms (50Hz) in case of power outage or voltage drop

Power outage reset delay time

40s

Operating temperature

-10°C to 60°C

Storage temperature

-30°C to 85°C

Dimensions (HxWxD) and weight

144x144x43 – 0.4 kg (unpacked)

Front plate protection

IP43